Ground snow load  35 psf
 Wind design  Wind speed (Vult) 115 mph 
 Topographic effects  No
 Special wind region  No
 Windborne debris zone  No
 Seismic Design Category  B
 Subject to damage from:  Weathering  Severe
 Frost line depth  36 inches
 Termite  Slight to moderate
 Ice barrier underlayment required  Yes
 Flood hazards  1978 (date of entry in NFIP) 2007/2017 (current FIRM map revision date)
 Air freezing index  ≤1,500º F
 Mean annual temperature  50º F
 MANUAL J DESIGN CRITERIA
 Elevation  5,160 feet
 Latitude  40
 Altitude correction factor  0.84
 Coincident wet bulb  60º F
 Indoor winter design relative humidity  30 percent
 Indoor winter design dry-bulb temperature  70º F
 Outdoor winter design dry-bulb temperature  7º F
 Heating temperature difference  63º F
 Daily range  High
 Indoor summer design relative humidity  50 percent
 Summer design grains  -35
 Indoor summer design dry-bulb temperature  75º F
 Outdoor summer design dry-bulb temperature  92º F
 Cooling temperature difference  17º F