Ground snow load |
35 psf |
Wind design |
Wind speed (Vult) |
115 mph |
Topographic effects |
No |
Special wind region |
No |
Windborne debris zone |
No |
Seismic Design Category |
B |
Subject to damage from: |
Weathering |
Severe |
Frost line depth |
36 inches |
Termite |
Slight to moderate |
Ice barrier underlayment required |
Yes |
Flood hazards |
1978 (date of entry in NFIP) 2007/2017 (current FIRM map revision date) |
Air freezing index |
≤1,500º F |
Mean annual temperature |
50º F |
MANUAL J DESIGN CRITERIA |
Elevation |
5,160 feet |
Latitude |
40 |
Altitude correction factor |
0.84 |
Coincident wet bulb |
60º F |
Indoor winter design relative humidity |
30 percent |
Indoor winter design dry-bulb temperature |
70º F |
Outdoor winter design dry-bulb temperature |
7º F |
Heating temperature difference |
63º F |
Daily range |
High |
Indoor summer design relative humidity |
50 percent |
Summer design grains |
-35 |
Indoor summer design dry-bulb temperature |
75º F |
Outdoor summer design dry-bulb temperature |
92º F |
Cooling temperature difference |
17º F |